Notes on the documentation
32 CX50x0 - Hardware Documentation
DVI-D connection
DVI-D connection (X200)
The DVI-D interface transfers digital data and is suitable for connecting a digital display. The resolution at the display
or the Beckhoff Control Panel depends on the distance from the display device. The maximum distance is 5 m.
Note
DVI-D interface
The DVI interface does not use VGA signals, so that the connection of CRT VGA monitors
to the CX1000 system using a DVI to VGA adapter is not possible.
DVI-D socket
Pin Assignment Pin Assignment Pin Assignment
1 TMDS Data 2- 9 TMDS Data 1- 17 TMDS Data 0-
2 TMDS Data 2+ 10 TMDS Data 1+ 18 TMDS Data 0+
3 TMDS Data 2/4 Shield 11 TMDS Data 1/3 Shield 19 TMDS Data 0/5 Shield
4 not connected 12 not connected 20 not connected
5 not connected 13 not connected 21 not connected
6 DDC Clock 14 + 5V Power 22 TMDS Clock Shield
7 DDC Data 15 Ground ( +5V, Analog H/V Sync) 23 TMDS Clock +
8 Analog Vertical Sync 16 Hot Plug Detect 24 TMDA Clock -
Resolution at the monitor
Resolution in pixels Distance of the interface from the monitor
1920 x 1200 5 m
1600 x 1200 5 m
1280 x 1024 5 m
1024 x 768 5 m
800 x 600 5 m
640 x 480 5 m