SIDNs
S00119Currentloopproportionalgain2
TheparametercontainsthevaluefortheproportionalgainofthePIcurrentcontrollerforthefieldgenerating
current(I_d).
Attributes
Name Value
Format udec
Datalength 16
Decimalpoint 1
Minvalue 0.0
Maxvalue 1000.0
Defaultvalue 0.0
Unit V/A
ChangeableinEtherCATstate PreOp,SafeOp,Op
Cyclictransfer No
Deviceparameter No
Relatedtointerfacerevision
Aslongasthisparameteris0,thecurrentcontrollerforthefieldgeneratingcurrentusesthesame
proportionalgainasthecontrollerforthetorque/forcegeneratingcurrent(S00106).
Note
IDNsinvolved
S‐0‐0106 [}78]