SIDNs
S00124Standstillwindow
Theparametercontainsavelocitythresholdvalue,whichisusedtodetectamotororaxisstandstill.
Attributes
Name Value
Format udec
Datalength 32
Decimalpoint 0
Minvalue 0
Maxvalue 17895697
Defaultvalue 89478
Unit rev/(2
30
ms)
ChangeableinEtherCATstate PreOp,SafeOp,Op
Cyclictransfer No
Deviceparameter No
Relatedtointerfacerevision
Ifthemagnitudeofactualvelocityfallsbelowthevalueofthisparameter,theaxisvelocityisinthesocalled
standstillwindow.Thisresultsinbit1ofS00013beingset.Inaddition,thiswindowisevaluatedinthe
AxisStateMachine.Furtheractionsareexecuted,dependingonthisthresholdvalue.Forexample,inmotors
withholdingbrake,thebrakeisengageddependingonthiswindow.Default(89478)equatesto5rpm.
Note
IDNsinvolved
S‐0‐0207 [}139],S‐0‐0013 [}16],S‐0‐0040 [}45]
Note
Additionalfunctionaldescription
SeealsoAxisStateMachinedocumentation(todo!).