SIDNs
Sx0109Motorpeakcurrent
ThisparametercontainstheRMSvalueofthemotorpeakcurrent.Ifthemotorpeakcurrentislowerthanthe
availablepeakcurrentoftheservodrive,thecurrentoftheservodriveisautomaticallylimitedtothevalueof
thisparameter.
Attributes
Name Value
Format udec
Datalength 32
Decimalpoint 3
Minvalue
Maxvalue
Defaultvalue
Unit A
ChangeableinEtherCATstate PreOp
Cyclictransfer No
Deviceparameter No
Relatedtointerfacerevision No
Note
Parametersetswitchoverispossible!
ThisIDNexistsasS00109;S10109;S20109;S30109;S40109;S50109;S60109
andS70109.Exfactory,allvaluesareidentical.