Beckhoff AX5000 S-IDN Parameters Manuale Utente Pagina 46

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 190
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 45
SIDNs
S00043Velocitypolarityparameter
Theparametercanbeusedtoinvertthepolarityofthevelocitydatainspecialapplications.
Attributes
Name Value
Format binary
Datalength 16
Decimalpoint 0
Minvalue 0
Maxvalue #x000F
Defaultvalue
Unit
ChangeableinEtherCATstate PreOp
Cyclictransfer No
Deviceparameter No
Relatedtointerfacerevision No
Thepolaritiesareswitchedattheinputandoutputoftheclosedcontrolloopandthereforedonotaffectthe
closedcontrolloopsinthedrive.Themotorshaftrotatesinaclockwisedirection(viewedfromthefrontonto
themotorshaft),ifthereisapositivevelocitysetvaluedifferenceandthereisnoinversion.
Bitpattern:
Bit Meaning
0 Velocitycommandvalue
Velocitycommandvalue
0=polaritynotinverted
1=polarityinverted
1 Additivevelocitycommandvalue
Additivevelocitycommandvalue
0=polaritynotinverted
1=polarityinverted
2 Velocityfeedbackvalue1
Velocityfeedbackvalue1
0=polaritynotinverted
1=polarityinverted
3 Velocityfeedbackvalue2
Velocityfeedbackvalue2
0=polaritynotinverted
1=polarityinverted
415 Reserved
AX5000IDNDescriptions46 Version3.1
Vedere la pagina 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 189 190