SIDNs
S00007Feedbackacquisitioncapturepoint(t4)
Thetimeofmeasurementoftheactualvaluesissynchronisedbythedrivewiththesynchronisationsignal
Sync1oftheEtherCATdistributedclock(DC).
Attributes
Name Value
Format UDEC
Datalength 16
Decimalpoint 0
Minvalue 0
Maxvalue 0
Defaultvalue 0
Unit µs
ChangeableinEtherCATstate PreOp
Cyclictransfer No
Deviceparameter No
Relatedtointerfacerevision No
Inthiswaythemastercanspecifythesameactualvaluemeasuringtimeforalldrivesthatoperateina
coordinatedway.Thisensuressynchronisationoftheactualvalueacquisitionfortherespectivedrives.
FromSafeOp,thedriveactivatesthemeasuringtimefortheactualvalues.
Note
IDNsinvolved
S‐0‐0002 [}10]
AX5000IDNDescriptions 11Version3.1