SIDNs
S00029MDTerrorcounter
AteachSync1timethedrivecheckswhethernewvalidMDTdataarepresent.Ifnot,thiscounteris
incremented.PossiblecausesoferrorarelateEtherCATtelegramsorincorrectlytransferredEtherCAT
telegramswithinvalidchecksums.
Attributes
Name Value
Format UDEC
Datalength 16
Decimalpoint 0
Minvalue
Maxvalue
Defaultvalue
Unit
ChangeableinEtherCATstate No
Cyclictransfer AT
Deviceparameter No
Relatedtointerfacerevision No
Thiscountershouldremainstaticatverylowvalues(1or2).Otherwise,thecauseshouldbeanalysed.